Kits Contains:
- five (5)
15' rolls
- five (5) dispensers with color match charts
- Range 0-400
PPM
About Quaternary Ammonium or "quats"
In some food processing plants, ""quats"" are
used to sanitize equipment prior to long periods when the equipment will
not be used. The "quats" are generally effective at killing vegetative
yeast and mold cells. They are less effective at killing bacterial
endospores and fungal spores.
Activity of the "quats" against bacteria
varies greatly, depending on the type of bacteria. Typical quat
concentrations used for food contact surfaces are 200 - 400 ppm, with a
follow-up running water rinse usually done prior to the next use of the equipment.
For certain "quats" and concentrations, a
post-use rinse is required by regulations. The "quats" work over a wide pH
range, with best activity in alkaline pH (click
here to see our simple pH testing strips). Hard water will diminish
the effectiveness of "quats", as will residues of food or cationic
surfactants.
Click
here for more information on the testing and use of "quats"
Mid Range QT-40 Test Kit
The mid-range test kit is the best
compromise and is favored by many of our regular customers who are
professionals in the field of sanitation. There is more
resolution of concentrations on the scale, and the somewhat higher
range allows more reading scope.

Mid Range QT-40 test kits are supplied
in packages of 5 rolls per shipment/order. There is no
"refill" available.
High Range Test Kit
When hard water or other conditions
compromise the effectiveness of a normal quat treatment, higher
concentrations are called for--concentrations that may be required to
exceed the normal range of our testing strips. In these
circumstances, use our High Range (0-1000 ppm) test strips (see
ordering details at left).

If you are uncertain, start with the High
Range version of the test--this will cover all concentrations that
would reasonably be used for this sanitizing operation.
If you are using hard water for sanitizing
rinse applications, generally the reading should be above 400 ppm for
sanitizing effectiveness.
High Range Kit Contains:
- five (5)
15' rolls
- five (5) dispensers with color match charts
- Range 0-1000 ppm
Refill package does not include
dispensers and only has on color match chart included in the bulk 5-roll
case. |